swegon logoswegon logoswegon logoswegon logo
MENUMENU
  • Explore
        • Explore the themes, topics, and trends impacting the built and natural environments.

        • All Topics
        • Wellness
          • COVID-19
          • Indoor Environmental Quality
        • Environment
          • Carbon and the Built Environment
        • Energy
          • Passive House
        • Swegon Solutions
  • Learn
        • Learn about our solutions and technology
        • Building Solutions
          • Multifamily Residential
          • Hotel
        • HVAC Technology
          • Psychrometrics
          • Chilled Beam Design
          • Active Airflow Control
          • Air to Air Energy Recovery
          • Mechanical Filtration
          • Ventilation
        • HVAC Systems
          • Water Source Heatpump
          • Variable Refrigerant Flow
          • Fan Coil System
        • Training
          • Continuing Education Courses
          • Comfort Training Center
          • Swegon on Tour
        • Standards and Codes
        • DesignEdge
        • References
  • Products
        • Everything you need to create the best indoor climate
        • Air Handling
          • GOLD NA RX Units
          • GOLD NA PX Units
          • GOLD NA SD Units
          • Gold Accessory Cabinet Section
          • Optional Accessories
        • Waterborne Units
          • View Chilled Beams
          • ADRIATIC VF and chilled Beams
          • FRB Chilled Beams
          • PACIFIC Chilled Beams
          • PARAGON Comfort Modules
          • PARASOL Comfort Modules
          • PRIMO Induction Modules
        • Air Distribution
          • React Damper
          • CLA
        • Swegon Passive House Solution
  • Support
        • We’re here to support you during all the phases of a project
        • Find Documents
        • Troubleshooting
        • ProSelect Software
  • About Swegon
        • Feel good inside
        • About Swegon NA
        • Our North American Brands
          • Commercial Ventilation
          • Noise Control
          • Vibration Isolation and Restraint Systems
        • Join Our Team
  • Find a Rep
  • Contact
  • Explore
    • All Topics
    • Wellness
      • COVID-19
      • Indoor Environmental Quality
    • Environment
      • Carbon and the Built Environment
    • Energy
      • Passive House
    • Swegon Solutions
  • Learn
    • Building Solutions
      • Multifamily Residential
      • Hotel
    • HVAC Technology
      • Psychrometrics
      • Chilled Beam Design
      • Active Airflow Control
      • Air to Air Energy Recovery
      • Mechanical Filtration
      • Ventilation
    • HVAC Systems
      • Water Source Heatpump
      • Variable Refrigerant Flow
      • Fan Coil System
    • Standards and Codes
    • Training
      • Continuing Education Courses
      • Comfort Training Center
      • Swegon on Tour
    • References
    • DesignEdge
  • Products
    • Swegon Passive House Solution
    • Air Handling
      • GOLD NA RX Units
      • GOLD NA PX Units
      • GOLD NA SD Units
      • Gold Accessory Cabinet Section
      • Optional Accessories
    • Waterborne Units
      • View Chilled Beams
      • ADRIATIC VF and chilled Beams
      • FRB Chilled Beams
      • PACIFIC Chilled Beams
      • PARAGON Comfort Modules
      • PARASOL Comfort Modules
      • PRIMO Induction Modules
    • Air Distribution
      • React Damper
      • CLA
  • Support
    • Find Documents
    • Troubleshooting
    • ProSelect Software
  • About Swegon
    • About Swegon NA
    • Our North American Brands
      • Commercial Ventilation
      • Noise Control
      • Vibration Isolation and Restraint Systems
    • Join Our Team
  • Find a Rep
  • Contact
Published by Tiffany Chan at May 11, 2020
Categories
Tags

100-0091_IMG-e1602651176522

Fan Coil System

HVAC System

Learn › HVAC Systems

Fancoil

A fan coil system is a decentralized HVAC system with terminal units at or near the occupied space serviced by a central heating and cooling plants.

fancoil model

Typical Fan coil Models

The fan coil system is used in many building types including hotels, multi-family residential, offices, schools and institutional. The terminal units are also called fan coils. They consist of an enclosure, fan and motor, coil with drain pan and a filter. Fan coils come in a wide range of configurations including the wall, ceiling exposed, horizontal ceiling concealed, stacked and large capacity.

Fan coils heat or cool by using hot water from a central heating plant and chilled water from a central chiller plant. The fan is powered by a small electric motor that circulates room air through the filter and coil. 4 pipe fan coil systems have two water loops (hot and chilled water) throughout the building connected to each fan coil. The water loops are insulated. Providing heating and cooling with water has a very low transportation (pump work) cost making fan coils an energy-efficient system choice. Further energy improvements can be found by using energy-efficient ECM motors in fan coils.

Fan coils have drain pans so consideration for condensate piping must be given. Providing enough pitch for good drainage can be a challenge.  In those cases, small condensate pumps with overflow safety switches can be used.

Temperature control is achieved by modulating control valves for the hot and chilled water. There is typically one or two fan coils per housing unit. Each fan coil has its own thermostat so each space has individual temperature control. With 4 pipe system, it is possible to have one space in cooling (south-facing) while another space is in heating (north-facing). There is only a small fan so generally, equipment sound levels are low. 4 pipe fan coils offer excellent occupant satisfaction. An alternative to 4 pipe fan coil is 2 pipe. There are significant cost savings (removes two pipes throughout the building) however the system can only be in heating or cooling. During shoulder weather, occupant dissatisfaction can occur when one occupant requires heating and another requires cooling. A variation of the two pipe system includes a small electric heater to provide some heating during shoulder seasons.

The primary heating is typically provided by a boiler. The primary cooling is provided by a chiller. This equipment is located in a mechanical room allowing maintenance with no impact on the building occupants. Using a heat pump chiller can improve the carbon footprint by deleting the need for a boiler (typically gas fired 0.9 COP) and drawing heat from the ambient air to heat the water (all electric COP= 2.5).

Ventilation unit with Hot and Chilled Water coils

Since the fancoil system is decentralized, a Dedicated Outdoor Air (DOAS) system is required to deliver outdoor air to maintain acceptable indoor air quality. It is good practice and often is a code requirement that the ventilation unit have some form of air to air energy recovery. Since the building will already have a heating and cooling plant,  it is common that the ventilation unit use hot water and chilled water for supplemental heating and cooling.

GSA_WBCS-Fan Coil System

Ventilation Unit Integrated into Fan Coil System

See More HVAC Systems

Stacked WSHP
Water Source Heatpump
LG-DUALCOOL-Long-piping
Variable Refrigerant Flow
Fan Coil System

Keep Exploring

Training

Swegon offers AIA and PDH certified course to support your professional development needs.

LEARN MORE

Products you'll need to create the best indoor climate in the world.

LEARN MORE
Share
Tiffany Chan
swegon logo
© 2020 Swegon North America
Privacy Policy   Accessible Customer Service Policy
Open toolbar

Accessibility Tools

  • Increase Text
  • Decrease Text
  • Grayscale
  • High Contrast
  • Negative Contrast
  • Light Background
  • Links Underline
  • Readable Font
  • Reset