GOLD NA RX Units
Air Handling Unit with rotary heat exchanger
GOLD enables designers to re-think system design.
- Temperature efficiency, heat exchanger up to 85%
- Air flows up to 16,300 cfm
- Variable speed control for rotary heat exchanger
- Recovers heat energy and cooling energy
- Optimized fan sizes give greater freedom to choose exactly the right size of air handling unit and fan variants to suit the needs of the installation. This also gives even greater possibilities to optimize the energy efficiency of the current project
Rotary heat exchanger RECOnomic / RECOsorptic
A rotary heat exchanger consists of an aluminum wheel with numerous small air passages. Energy is transferred between the supply air and extract air or vice versa when the wheel rotates. This is the most energy-efficient heat recovery method with a temperature efficiency that always exceeds 80%. Thanks to a patented design with turbulent flow in the air passages, RECOnomic attains a uniquely high degree of energy efficiency.
Swegon’s rotary heat exchanger is also available in a sorption version (RECOsorptic), which increases the energy efficiency further through the product dehumidifying or recovering moisture depending on the conditions and needs.
Full control over air quality
On account of the unique combination of purging sector and Carry-Over Control functionality, the risk of leakage between the extract air and supply air is minimized, which ensures the building is always ventilated with fresh air.
Air Quality Control Feature
Perfect Balance
Vital for our well-being
Swegon GOLD RX Air Quality Control Feature
To minimize cross-contamination with rotary heat exchangers it is critical that the pressure gradient from the supply air path to the return air path be properly maintained. All GOLD RX units come with adjustable pressure baffles that are adjusted during commissioning to deliver the correct pressure gradient (0 to 0.08 inches w.c. (0-20 Pa)).
Air Quality Control Feature Menu in IQLogic Controller
Swegon now offers Air Quality Control dynamic pressure compensation to maintain the correct pressure gradient over a wide range of operating conditions. Demand Control Ventilation (VAV) , filter loading and building pressurization control are all examples that cause conditions to change and the Air Quality Control feature will automatically adjust to meet these changes.
The Swegon IQLogic controller monitors the pressure gradient within the RX unit and automatically adjusts a damper in the return air path to maintain the correct gradient. This can all be set up through the IQNavigator.
For more information refer to TBLZ186.pdf which can be found using the document finder.
GOLD RX Sizes
For GOLD RX size details, please contact Swegon or your local Swegon rep
GOLD
Model-Size |
Air Flow Rate
no Cooling Coil at 1.5 inWC ESP
|
|
L
|
W
|
H
|
Number of fans
|
Power Connection
|
Full Load Amps (FLA)
|
Minimun Circuit Ampacity (MCA)
|
Recommended Fuse/ Breaker Size(RFS)
|
Shipping sections
|
The number of sections the divided to
|
|
|
Min
|
Max
|
in
|
in
|
in
|
|
|
A
|
A
|
|
|
|
|
|
CFM
|
|
|
|
|
|
|
|
|
|
|
|
|
RX-05
|
413
|
1377
|
61
|
32.5
|
43.1
|
1
|
220V/1/60HZ
|
11.9
|
13.27
|
15
|
1
|
1
|
|
RX-07
|
450
|
1500
|
65.7
|
39.2
|
49.6
|
1
|
220V/1/60HZ
|
11.9
|
13.27
|
15
|
1
|
1
|
|
RX-08
|
525
|
1750
|
65.7
|
39.2
|
49.6
|
2
|
220V/1/60HZ
|
11.9
|
13.27
|
15
|
1
|
2
|
|
RX-11
|
585
|
1950
|
75.2
|
47.2
|
57.9
|
1
|
220V/1/60HZ
|
12.5
|
13.92
|
15
|
1
|
3
|
|
RX-12
|
885
|
2950
|
75.2
|
47.2
|
57.9
|
2
|
460V/3/60HZ
|
8
|
8.79
|
15
|
1
|
3
|
|
|
|
|
|
|
|
|
600V/3/60HZ
|
6.1
|
6.68
|
15
|
|
|
|
RX-14
|
1005
|
1005
|
83.9
|
55.1
|
68
|
1
|
460V/3/60HZ
|
8
|
8.79
|
15
|
1
|
3
|
|
|
|
|
|
|
|
|
600V/3/60HZ
|
6.1
|
6.68
|
15
|
|
|
|
RX-20
|
1260
|
4200
|
83.9
|
55.1
|
68
|
2
|
460V/3/60HZ
|
11.8
|
13.07
|
15
|
1
|
3
|
|
|
|
|
|
|
|
|
600V/3/60HZ
|
8.9
|
9.83
|
15
|
|
|
|
RX-25
|
1425
|
4750
|
91
|
63
|
75.2
|
1
|
460V/3/60HZ
|
11.8
|
13.07
|
15
|
2
|
3
|
|
|
|
|
|
|
|
|
600V/3/60HZ
|
8.9
|
9.83
|
15
|
|
|
|
RX-30
|
1950
|
6500
|
91
|
63
|
75.2
|
2
|
460V/3/60HZ
|
16.8
|
18.69
|
25
|
2
|
3
|
|
|
|
|
|
|
|
|
600V/3/60HZ
|
12.9
|
14.33
|
20
|
|
|
|
RX-35
|
2250
|
7500
|
106
|
78.3
|
88.9
|
1
|
460V/3/60HZ
|
16.8
|
18.69
|
25
|
2
|
3
|
|
|
|
|
|
|
|
|
600V/3/60HZ
|
12.9
|
14.33
|
20
|
|
|
|
RX-40
|
2700
|
9000
|
106
|
78.3
|
88.9
|
2
|
460V/3/60HZ
|
22
|
24.54
|
30
|
2
|
3
|
|
|
|
|
|
|
|
|
600V/3/60HZ
|
16.9
|
18.83
|
25
|
|
|
|
RX-50
|
3000
|
10000
|
106
|
91.3
|
94
|
1
|
460V/3/60HZ
|
22
|
24.54
|
30
|
2
|
3
|
|
|
|
|
|
|
|
|
600V/3/60HZ
|
16.9
|
18.83
|
25
|
|
|
|
RX-60
|
4110
|
137000
|
106
|
91.3
|
94
|
2
|
460V/3/60HZ
|
40.6
|
43.02
|
50
|
2
|
3
|
|
|
|
|
|
|
|
|
600V/3/60HZ
|
31.1
|
32.93
|
40
|
|
|
|
RX-70
|
4740
|
15800
|
124.5
|
103.8
|
107.9
|
1
|
460V/3/60HZ
|
40.6
|
43.02
|
50
|
2
|
5
|
|
|
|
|
|
|
|
|
600V/3/60HZ
|
31.1
|
32.93
|
40
|
|
|
|
RX-80
|
5250
|
17500
|
124.5
|
103.8
|
107.9
|
2
|
460V/3/60HZ
|
43.1
|
45.69
|
50
|
2
|
5
|
|
|
|
|
|
|
|
|
600V/3/60HZ
|
33.1
|
35.04
|
40
|
|
|
Size RX |
Air Flow Rate at 1 or 1.5 inWC ESP (No Cooling Coil ) |
|
Max Air Flow Rate to maintain 500 FPM face velocity in cooling coil |
Passive House |
L |
W |
H |
Number of fans |
Power Connection |
Full Load Amps (FLA) |
Minimum Circuit Ampacity (MCA) |
Recommended Fuse /Breaker Size (RFS) |
Number of Shipping sections (End connections) |
The number of sections the unit can be divided to (End connections) |
||||
|
|
ESP |
Min (CFM) |
Max (CFM) |
|
Max (CFM) |
ESP |
Max (CFM) |
in |
in |
in |
|
|
|
|
|
|
|
RX-05 |
1″ |
360 |
1370 |
839 |
0.75 |
647 |
61 |
32.5 |
43.1 |
2 |
220V/1/60HZ |
11.9 |
13.27 |
15 |
1 |
1 |
||
RX-07 |
1″ |
330 |
1580 |
1313 |
0.90 |
1041 |
65.7 |
39.2 |
49.6 |
2 |
220V/1/60HZ |
11.9 |
13.27 |
15 |
1 |
1 |
||
RX-08 |
1″ |
870 |
1850 |
1313 |
0.90 |
1118 |
65.7 |
39.2 |
49.6 |
2 |
220V/1/60HZ |
11.9 |
13.27 |
15 |
1 |
1 |
||
RX-11 |
1″ |
780 |
2000 |
2250 |
0.90 |
1571 |
75.2 |
47.2 |
57.9 |
2 |
220V/1/60HZ |
12.5 |
13.92 |
15 |
1 |
3 |
||
RX-12 |
1″ |
1300 |
2960 |
2250 |
0.90 |
1724 |
75.2 |
47.2 |
57.9 |
2 |
460V/3/60HZ |
8 |
8.79 |
15 |
1 |
3 |
||
|
|
|
|
|
|
|
|
|
|
|
600V/3/60HZ |
6.1 |
6.68 |
15 |
|
|
||
RX-14 |
1″ |
1220 |
3470 |
3438 |
1.00 |
2648 |
83.9 |
55.1 |
68 |
2 |
460V/3/60HZ |
8 |
8.79 |
15 |
1 |
3 |
||
|
|
|
|
|
|
|
|
|
|
|
600V/3/60HZ |
6.1 |
6.68 |
15 |
|
|
||
RX-20 |
1″ |
1950 |
4440 |
3438 |
1.00 |
2525 |
83.9 |
55.1 |
68 |
2 |
460V/3/60HZ |
11.8 |
13.07 |
15 |
1 |
3 |
||
|
|
|
|
|
|
|
|
|
|
|
600V/3/60HZ |
8.9 |
9.83 |
15 |
|
|
||
RX-25 |
1″ |
1850 |
5180 |
4875 |
1.15 |
3372 |
91 |
63 |
75.2 |
2 |
460V/3/60HZ |
11.8 |
13.07 |
15 |
1 |
3 |
||
|
|
|
|
|
|
|
|
|
|
|
600V/3/60HZ |
8.9 |
9.83 |
15 |
|
|
||
RX-30 |
1″ |
2880 |
6410 |
4875 |
1.15 |
2742 |
91 |
63 |
75.2 |
2 |
460V/3/60HZ |
16.8 |
18.69 |
25 |
1 |
3 |
||
|
|
|
|
|
|
|
|
|
|
|
600V/3/60HZ |
12.9 |
14.33 |
20 |
|
|
||
RX-35 |
1.5″ |
3000 |
6860 |
8026 |
1.25 |
4708 |
106 |
78.3 |
88.9 |
2 |
460V/3/60HZ |
16.8 |
18.69 |
25 |
2 |
3 |
||
|
|
|
|
|
|
|
|
|
|
|
600V/3/60HZ |
12.9 |
14.33 |
20 |
|
|
||
RX-40 |
1.5″ |
4740 |
8700 |
8026 |
|
|
106 |
78.3 |
88.9 |
2 |
460V/3/60HZ |
22 |
24.54 |
30 |
2 |
3 |
||
|
|
|
|
|
|
|
|
|
|
|
600V/3/60HZ |
16.9 |
18.83 |
25 |
|
|
||
RX-50 |
1.5″ |
4300 |
9420 |
10000 |
1.30 |
5885 |
106 |
91.3 |
94 |
2 |
460V/3/60HZ |
22 |
24.54 |
30 |
2 |
3 |
||
|
|
|
|
|
|
|
|
|
|
|
600V/3/60HZ |
16.9 |
18.83 |
25 |
|
|
||
RX-60 |
1.5″ |
7000 |
13770 |
10000 |
|
|
106 |
91.3 |
94 |
4 |
460V/3/60HZ |
40.6 |
43.02 |
50 |
2 |
3 |
||
|
|
|
|
|
|
|
|
|
|
|
600V/3/60HZ |
31.1 |
32.93 |
40 |
|
|
||
RX-70 |
1.5″ |
6640 |
15890 |
13971 |
1.35 |
5885 |
124.5 |
103.8 |
107.9 |
4 |
460V/3/60HZ |
40.6 |
43.02 |
50 |
2 |
5 |
||
|
|
|
|
|
|
|
|
|
|
|
600V/3/60HZ |
31.1 |
32.93 |
40 |
|
|
||
RX-80 |
1.5″ |
11000 |
17000 |
13971 |
|
|
124.5 |
103.8 |
107.9 |
4 |
460V/3/60HZ |
43.1 |
45.69 |
50 |
2 |
5 |
||
|
|
|
|
|
|
|
|
|
|
|
600V/3/60HZ |
33.1 |
35.04 |
40 |
|
|
SUSTAINABLE PRODUCT CERTIFICATION
- Passive House Institute (PHI).. Two GOLD RX models are certified by the Passive House Institute as Large Air Handling Units with heat recovery. GOLD RX with an aluminum RECOnomic rotor meets PHI requirements for heat recovery rate. GOLD RX with RECOsorptic rotor meets PHI heat recovery requirements and also includes certified latent heat recovery values. Certification applies to specific sizes, airflow rates and external pressures, in accordance with Passive House Institute program requirements. PHI certificates for both models are available below. Swegon’s Passive House Solutions include GOLD RX to maximize heat recovery while minimizing electrical consumption.
Passive House Institute Certification Summary
|
|
SCSR-1A Concrete
|
SCSR-4A Concrete
|
|||
|
||||||
Rotor Type
|
RECOnomic
|
RECOsorptic
|
RECOsorptic
|
|||
Rotor Construction
|
Aluminum
|
Sorption-coated Aluminum
|
Sorption-coated Aluminum
|
|||
Climate
|
Cool, Temperature
|
Cool, Temperature
|
Very Hot
|
|||
Certified Heat Recovery Rate
|
|
|
|
|||
Sensible
|
>84%
|
>80%
|
>70%
|
|||
Latent
|
n/a
|
>90%
|
>90%
|
|||
Airflow range CFM
|
320 -5300
|
320-5850
|
320-5850
|
- Living Building Challenge (LBC). When configured with the Declare Label option, GOLD RX is Living Building Challenge Compliant. GOLD RX is part of Swegon’s Healthy Building Solution. Details of the GOLD Declare label are available from International Living Futures Institute (ILFI). For more information about applying GOLD RX air handling units in projects to maximize energy savings, please visit: https://swegonnorthamerica.com/swegon-healthy-building-solution/. The Declare label also contributes to the materials requirements of WELL, Collaborative for High-Performance Schools (CHPS) Enterprise Green Communities (EGC)
- Click here to read more about the application of GOLD RX with Declare Label option
- NEEA (Northwest Energy Efficiency Alliance). GOLD RX is compliant with the prescriptive requirements of Northwest Energy Efficiency Alliance Very High Efficiency Dedicated Outside Air System (NEEA VHE DOAS). Very High Efficiency DOAS (VHE DOAS) System Requirements. Swegon GOLD RX Models are included in NEEA VHE DOAS Compliant Product List
- signifying that they are compliant with NEEA’s prescriptive requirements for thermal efficiency, fan efficacy, cross-flow leakage/Exhaust Air Transfer Ratio and minimum capabilities. For details about the VHE DOAS program, visit the Better Bricks website.
Find Documents
You can find more documents on our document search page.
Keep Exploring
Swegon offers AIA and PDH certified course to support your professional development needs.