swegon logo
Product Search

Search Products

Search
Generic filters
  • DOCUMENT SEARCH
  • GLOBAL
Menu
  • DOCUMENT SEARCH
  • GLOBAL
Contact
  • Blog

    Explore the themes, and trends impacting the built and natural environment

    all topics
    wellness
    • COVID-19
    • Indoor Environmental Quality
    Environment
    • Carbon and the Built Environment
    Energy
    • Passive House
    swegon solutions
  • Learn

    Learn about our solutions and technology

    building solutions
    • Multifamily Residential
    • Hotel
    hvac technology
    • Humidity Recovery and Control
    • Pyschrometrics
    • Chilled Beam Design
    • Active Airflow Control
    • Air to Air Energy Recovery
    • Mechanical Filtration
    • Ventilation
    hvac system
    • Water Source Heatpump
    • Variable Refrigerant Flow
    • Fan Coil System
    Standard and Codes
    Training
    • Continuing Education Courses
    • Comfort Training Center
    • Swegon on Tour
    References
    • Hotels
    • Commercial
    • Healthcare
    • Education
    • Apartment
    • Theatre and Museums
    • Multi-family Residential
    • Data Center
  • Products

    Explore the themes, and trends impacting the built and natural environment

    Air Distribution
    • React Damper
    • CLA
    Swegon Solutions
    • Passive House Solutions
    • Sustainable Building Solutions
    Air Handling UNITS
    GOLD Handling Units
    • Gold RX Units
    • Gold PX Units
    • Gold SD Units
    GOLD Accessories
    • Optional Accessories
    • Gold Accessory-Cabinet Section
    CASA Air Handling Units
    • CASA R3 Genius
    • CASA R5 Genius
    • CASA R7 Genius
    • CASA R9 Genius
    CASA Accessories
    • CASA Genius Control
    • CASA SEC
    • CASA SEM
    • CASA SET
    • CASA Sensor Package
    CASA Duct Accessories
    • Electric Duct Heater
    • Waterborne Air Coolers
    • Waterborne Air Heaters
    • Dampers
    • Gold RX Units
    • Gold PX Units
    • Gold SD Units
    • Optional Accessories
    • Gold RX Units
    • Gold PX Units
    • Gold SD Units
    GOLD Accessories

    Gold Accesory Cabinet Section

    CASA Accessories
    CASA Air Handling
    CASA R3 Genius
    CASA R5 Genius
    CASA R7 Genius
    CASA R9 Genius
    CASA SEC
    CASA SEM
    CASA SET
    CASA WSTC
    CASA Sensor package Swegon Casa Genius
    Waterborne room units
    • View Chilled Beams
    • ADRIATIC VF and chilled Beams
    • FRB Chilled Beams
    • PACIFIC Chilled Beams
    • PARAGON Comfort Modules
    • PARASOL Comfort Modules
    • PRIMO Induction Modules
  • Support

    We’re here to support you during all the phases of a project

    find documents
    Product Service and Support
    proselect software
    Application Assistance
  • About Swegon

    Feel good inside

    About Swegon NA
    • Swegon North America News
    our north american brands
    • Commercial Ventilation
    • Noise Control
    • Vibration Isolation and Restraint Systems
    Join Our Team
  • Find a Rep
  • Blog

    Explore the themes, and trends impacting the built and natural environment

    all topics
    wellness
    • COVID-19
    • Indoor Environmental Quality
    Environment
    • Carbon and the Built Environment
    Energy
    • Passive House
    swegon solutions
  • Learn

    Learn about our solutions and technology

    building solutions
    • Multifamily Residential
    • Hotel
    hvac technology
    • Humidity Recovery and Control
    • Pyschrometrics
    • Chilled Beam Design
    • Active Airflow Control
    • Air to Air Energy Recovery
    • Mechanical Filtration
    • Ventilation
    hvac system
    • Water Source Heatpump
    • Variable Refrigerant Flow
    • Fan Coil System
    Standard and Codes
    Training
    • Continuing Education Courses
    • Comfort Training Center
    • Swegon on Tour
    References
    • Hotels
    • Commercial
    • Healthcare
    • Education
    • Apartment
    • Theatre and Museums
    • Multi-family Residential
    • Data Center
  • Products

    Explore the themes, and trends impacting the built and natural environment

    Air Distribution
    • React Damper
    • CLA
    Swegon Solutions
    • Passive House Solutions
    • Sustainable Building Solutions
    Air Handling UNITS
    GOLD Handling Units
    • Gold RX Units
    • Gold PX Units
    • Gold SD Units
    GOLD Accessories
    • Optional Accessories
    • Gold Accessory-Cabinet Section
    CASA Air Handling Units
    • CASA R3 Genius
    • CASA R5 Genius
    • CASA R7 Genius
    • CASA R9 Genius
    CASA Accessories
    • CASA Genius Control
    • CASA SEC
    • CASA SEM
    • CASA SET
    • CASA Sensor Package
    CASA Duct Accessories
    • Electric Duct Heater
    • Waterborne Air Coolers
    • Waterborne Air Heaters
    • Dampers
    • Gold RX Units
    • Gold PX Units
    • Gold SD Units
    • Optional Accessories
    • Gold RX Units
    • Gold PX Units
    • Gold SD Units
    GOLD Accessories

    Gold Accesory Cabinet Section

    CASA Accessories
    CASA Air Handling
    CASA R3 Genius
    CASA R5 Genius
    CASA R7 Genius
    CASA R9 Genius
    CASA SEC
    CASA SEM
    CASA SET
    CASA WSTC
    CASA Sensor package Swegon Casa Genius
    Waterborne room units
    • View Chilled Beams
    • ADRIATIC VF and chilled Beams
    • FRB Chilled Beams
    • PACIFIC Chilled Beams
    • PARAGON Comfort Modules
    • PARASOL Comfort Modules
    • PRIMO Induction Modules
  • Support

    We’re here to support you during all the phases of a project

    find documents
    Product Service and Support
    proselect software
    Application Assistance
  • About Swegon

    Feel good inside

    About Swegon NA
    • Swegon North America News
    our north american brands
    • Commercial Ventilation
    • Noise Control
    • Vibration Isolation and Restraint Systems
    Join Our Team
  • Find a Rep
swegon logo
Published by Tiffany Chan at Oct 13, 2020
Categories
Tags

GOLD Accessories

Products › Air Handling     |     Introduction     Accessories     Documents

GOLD can be much more than just an energy recovery unit. By adding additional accessory sections to the GOLD RX, PX or SD main units, the core energy recovery section can be transformed into an outdoor unit, include preheat, reheat cooling, additional filtration, noise control and many other configurations.

Click below to see the available accessory sections.

Damper In Casing - ACSA

ACSA dampers are used as shut-off dampers or forced airflow dampers. Sizes 012 – 80 can also be used for other applications, such as outdoor air dampers for the ReCO2 control function.

Shut-off dampers are normally used if the air handling unit is idle during some period, for example at night, or if an air heater for hot water without anti-frost burst protection is used.

To be installed for horizontal airflow. Complete with damper actuator for 24 V. The actuator can be selected with spring return or on/off actuation. ACSA sizes 012 – 80 are also available with modulating type actuator with spring return.

Hot Water Coil section - ACLA

The ACLA section is used for reheating the supply air. The section uses hot water or steam as the heating medium.

In many applications, it is possible to omit the air heater for reheat if the air handling unit control system is operated in the temperature
regulation mode according to the ERS model and when the efficient rotary heat exchanger is in use.

The water coil includes steel stub outs with manual drain and vent plugs, The ACKA water coils can be selected in AHU Design software. To be installed for horizontal airflow.

Valve set
The TBVL valve set with 2-way valve, actuator and connection cable with quick-fit connector can be ordered for the chilled water coil.
Temperature sensor water for reading incoming or outgoing cooling medium temperatures as an option.

If you use a valve of your own, you can instead select a set of electrical connection components. This set contains a connection cable with quick-fit connector, resistor and insertion type or strap-on sensor.

Preheat Coil Section - ACLF

The ACLF section is used for preheating the supply air. The section uses hot water as the heating medium. Install the ACLF in the outdoor air path to the ERV.

When it is cold outside and the humidity is high, preheating the incoming outdoor air will prevent condensation in the air filters (hoare frosting). The function can also be utilized when it is extremely cold outdoors and it is desirable to heat the air up to -4°F (-20°C), for instance.

In combination with the counterflow heat exchanger, it can also be of interest to preheat the air to be spared having to let it bypass the
heat exchanger. The coil includes steel stub outs with manual drain and vent plugs, The ACKA coils can be selected in AHU Design software. To be installed for horizontal airflow.

Valve set
The TBVL valve set with 2-way valve, actuator and connection cable with quick-fit connector can be ordered for the chilled water coil.
Temperature sensor water for reading incoming or outgoing cooling medium temperatures as an option.

If you use a valve of your own, you can instead select a set of electrical connection components. This set contains a connection cable
with quick-fit connector, resistor and insertion type or strap-on sensor.

Chilled Water Coil Section - ACKA

The ACKA cooling coil sections are used for cooling the supply air with chilled water as the cooling medium.

The coil includes steel stub outs with manual drain and vent plugs, The ACKA coils can be selected in AHU Design software. To be installed for horizontal airflow.

Valve set
The TBVL valve set with 2-way valve, actuator and connection cable with quick-fit connector can be ordered for the chilled water coil. Temperature sensor water for reading incoming or outgoing cooling medium temperatures as an option. If you use a valve of your own, you can instead select a set of electrical connection components. This set contains a connection cable with quick-fit connector, resistor and insertion type or strap-on
sensor.

DX Coil Section - ACKC

The ACKC cooling coil sections are used for cooling the supply air with refrigerant as the cooling medium. The ACKC coils can be selected by the factory to work with most DX and VRF systems. To be installed for horizontal airflow.

Electric Reheat Coil Section - ACLE

ACLE electric heater is used for reheating of the supply air or for certain preheating needs of outdoor air. The heater includes a separate disconnect from the unit and SCR control on at least one stage of heating for fully modulating temperature control. In many applications, it is possible to omit the air heater for reheat if the air handling unit control system is operated in the temperature regulation mode according to the ERS model and when the efficient rotary heat exchanger is in use. To be installed for horizontal airflow. The heater requires a separate power connection from the unit.

Combo Coil Section - ACLK

The ACLK coil section has both a hot water and chilled water coil for heating and cooling. There is an access section between the coils including an access door. The coils can be in either heat-cool or cool-heat configuration. The cooling coil can be either chilled water or DX and includes a double sloped stainless steel drain pan. The coils include steel stub outs with manual drain and vent plugs, The ACLK coils can be selected in AHU Design software.

To be installed for horizontal airflow.

Valve Set
The TBVL valve set with 2-way valve, actuator and connection cable with quick-fit connector can be ordered for the chilled water and hot water coils. Temperature sensor water for reading incoming or outgoing cooling medium temperatures as an option. If you use a valve of your own, you can instead select a set of electrical connection components. This set contains a connection cable with quick-fit connector, resistor and insertion type or strap-on sensor.

Combo Electric Heat and Coil Section - ACEK

Electric heater and either chilled water or DX coil complete with double sloped stainless steel drain pan

Recirculating Section - ACBR

The ACBR air recirculation section is an extra unit section that has a motor-driven damper (on/off or modulating) in the intermediate level.
The air recirculation section is available for the size 011 and larger GOLD RX and PX units. The ACBR can be used for mixing outdoor air and return air during operation (RECO2) or for 100% recirculation during night setback. The GOLD PX cannot be used for the ReCO function2.

Spacer Section - ACGA

The ACGA spacer section is used when provision for spacing is required. The ACGA comes in either 22.5″ (565 mm) or 33.5″ (850 mm) lengths and must be installed for horizontal airflow.

Access Section - ACIA

The ACIA spacer section is used when provision for inspection is required. The ACIA inspection section is available in two variants, with inspection door the entire length of the section (sizes 005-80), or split cover panel/inspection door (sizes 005-040 – long length). The ACIA comes in either 22.5″ (565 mm) or 33.5″ (850 mm) lengths and must be installed for horizontal airflow.

Multisection - ACFE

The ACFE multisection is an extra unit section, available in 22.5″ (565 mm) or 33.5″ (850 mm) lengths, with intermediate deck and optional combinations of cover panels/inspection doors on the inspection side. The cover panels are easy to dismantle.

Up to two multisections can be used in one air handling unit. The multisection is available for the size 011 and larger GOLD RX and CX units. The multisection can be located between the other unit sections of the GOLD unit. See the example above.

The multisection is available, as a special version, with installed accessories from the factory, for example, an air heater/air cooler, dampers, etc..

Duct Cross Over Section - TCRS

Duct crossover section
The duct crossover section for GOLD PX units is designed for use when you need to have the return air and/or the supply air connection in the upper level. This may be necessary if space available is restricted or for example when replacing older AHUs with new ones that have fans in the upper level. It is also possible to use the duct crossover section as a fire bypass. The duct crossover section is available for GOLD PX size 011-040.

Final Filter Section-TCFB

The TCFB final filter section should be installed in ventilation systems where further filtration of the supply air is required. Install the final filter section in the supply air downstream of the air handling unit. Factory installed pressure sensor is standard. The alarm limit and current filter pressure can be read on the hand-held micro terminal of the GOLD unit. To be installed for horizontal airflow.

Find Documents

You can find more documents on our document search page.

LinkTitleArticleProduct GroupDocument TypeFormatdocument_type_hfilter
Sensor, Temperature, Return Air TBLZ-1-76TBLZ-1-76Air Handling, GOLD, GOLDPX, GOLDRXInstructionspdfinstructions
Humidity Sensor, wall TBLZ-4-31-6TBLZ-4-31-6Air Handling, GOLD, GOLDRXInstructionspdfinstructions
Humidity Sensor, duct TBLZ-4-31-1/2/4/5TBLZ-4-31Air Handling, GOLD, GOLDRXInstructionspdfinstructions
TBLZ-1-64 connection kit installation, GOLDTBLZ-1-64Air Handling, GOLD, GOLDRXInstructionspdfinstructions
GOLD F IQLogic Function GuideAir Handling, Controls, GOLD, GOLDPX, GOLDRXEngineering, Instructionspdfengineering instructions
GOLD RX Hygrostatic rotor controller function guideAir Handling, Controls, GOLD, GOLDRXEngineering, Instructionspdfengineering instructions
Passive House (PHI) Certificate GOLD RX with heat recovery onlyAir Handling, GOLD, GOLDRXEngineering, Qualitypdfengineering quality
Passive House (PHI) Certificate GOLD RX with humidity recoveryAir Handling, GOLD, GOLDRXEngineering, Qualitypdfengineering quality
GOLD Alarm Trouble Shooting Tree OldServiceAir Handling, GOLDInstructionspdfinstructions
Gold RX Declare BrochureAir Handling, GOLD, GOLDRXBrochure, Instructions, Otherpdfbrochure instructions other
Installation Instructions GOLD SD F VersionGOLDAir Handling, GOLDInstructionspdfinstructions
Installation Instructions GOLD RX, PX F VersionGOLDAir Handling, GOLDInstructionspdfinstructions
Operation and Maintenance GOLD NA SDGOLDAir Handling, GOLDInstructionspdfinstructions
Operation and Maintenance GOLD NA PXGOLDAir Handling, GOLDInstructionspdfinstructions
Operation and Maintenance GOLD NA RXGOLDAir Handling, GOLDInstructionspdfinstructions
Commissioning Record, Program Version 1.32GOLDAir Handling, GOLDInstructionspdfinstructions
Operation Manual, hand held terminal IQNavigatorGOLDAir Handling, GOLDInstructionspdfinstructions
Function Manual – User, Program Version 1.31GOLDAir Handling, GOLDInstructionspdfinstructions
Function Manual – Installation, Program Version 1.32GOLDAir Handling, GOLDInstructionspdfinstructions
Optical Smoke Detector with Built in Control UnitTBLZ172Air Handling, GOLDInstructionspdfinstructions
Manual for Alarms and information messages, Program Version 1.32GOLDAir Handling, GOLDInstructionspdfinstructions
Air Quality ControlTBLZ-186Air Handling, GOLDInstructionspdfinstructions
Whistler Housing Authority GOLD and REACT Case StudyGOLD, ReactAir Distribution, Air Handling, GOLD, REACTApplicationspdfapplications
Actuator CoverTBXZ-81Air Handling, GOLDInstructionspdfinstructions
Installation Instructions-GOLD CO2 sensor-duct mountedTBLZ-74Air Handling, GOLDInstructionspdfinstructions
All Year Comfort InstallationTBLZ259 AYC InstallAir Handling, GOLDInstructionspdfinstructions
Temp Sensor Ext Cable KitTBLZ05 Ext Cable KitAir Handling, GOLDInstructionspdfinstructions
Pressure Sensor Ext Cable KitTBLZ213 Ext Cable KitAir Handling, GOLDInstructionspdfinstructions
Protocol – Complete Documentation v1.10 and newer (GOLD)BACnet IPAir Handling, GOLDInstructionszipinstructions
Edit Object Name/Description for BACnet IPBACnet IPAir Handling, GOLDInstructionspdfinstructions
GOLD Pressure SensorTBLZ-1-23Air Handling, GOLDInstructionspdfinstructions
GOLD Alarm Trouble Shooting Tree Oct 2022ServiceAir Handling, GOLDInstructionspdfinstructions
GOLD SYSTEM APPLICATION DAIKIN VRV IntegrationGOLDAir Handling, GOLDProduct Sheetpdfproduct-sheet
GOLD NA E Passive House BrochureGOLDAir Handling, GOLDBrochurepdfbrochure
GOLD Daikin VRF Control WiringGOLDAir Handling, GOLDEngineeringpdfengineering
GOLD RX50-80 Std Power WiringWiring DiagramAir Handling, GOLDEngineeringpdfengineering
GOLD RX12-40 Std Power WiringWiring DiagramAir Handling, GOLDEngineeringpdfengineering
GOLD RX05-11 Std Power WiringWiring DiagramAir Handling, GOLDEngineeringpdfengineering
GOLD Mitsubishi PAC Panel Control WiringWiring DiagramAir Handling, GOLDEngineeringpdfengineering
GOLD HW+CW Recirculation Control WiringWiring DiagramAir Handling, GOLDEngineeringpdfengineering
GOLD HW+CW Dehumidifcation Control WiringWiring DiagramAir Handling, GOLDEngineeringpdfengineering
GOLD Electric Preheat+Electric Reheat+CW Control WiringWiring DiagramAir Handling, GOLDEngineeringpdfengineering
GOLD Electric Preheat+Electric Reheat Control WiringWiring DiagramAir Handling, GOLDEngineeringpdfengineering
GOLD CW+Eletric Reheat Control WiringWiring DiagramAir Handling, GOLDEngineeringpdfengineering
GOLD Electric Reheat Control WiringWiring DiagramAir Handling, GOLDEngineeringpdfengineering
GOLD HW Preheat+HW+CW Control WiringWiring DiagramAir Handling, GOLDEngineeringpdfengineering
GOLD HW+CW Control WiringWiring DiagramAir Handling, GOLDEngineeringpdfengineering
GOLD Control WiringWiring DiagramAir Handling, GOLDEngineeringpdfengineering
GOLD SYSTEM APPLICATION SAMSUNG VRF IntegrationGOLDAir Handling, GOLDProduct Sheetpdfproduct-sheet
GOLD SYSTEM APPLICATION WATER SOURCE HEATPUMP (WSHP) – BOILER TOWERGOLDAir Handling, GOLDProduct Sheetpdfproduct-sheet
GOLD SYSTEM APPLICATION Chilled BeamsGOLDAir Handling, GOLD, PACIFIC, PARAGON, PARASOL, PRIMO, Room UnitsProduct Sheetpdfproduct-sheet
GOLD SYSTEM APPLICATION MITSUBISHI ELECTRIC VRF IntegrationGOLDAir Handling, GOLDProduct Sheetpdfproduct-sheet
GOLD SYSTEM APPLICATION LG VRF IntegrationGOLDAir Handling, GOLDProduct Sheetpdfproduct-sheet
GOLD E FunctionsGOLDAir Handling, GOLDProduct Sheetpdfproduct-sheet
Passivehouse Certificate 2020GOLDAir Handling, GOLDQualitypdfquality
GOLD NA E Passivehouse Reference ProjectsGOLDAir Handling, GOLDBrochurepdfbrochure
GOLD Control Sequence optionsGOLDAir Handling, GOLDProduct Sheetpdfproduct-sheet
GOLD IQLogicGOLDAir Handling, GOLDProduct Sheetpdfproduct-sheet
GOLD NA E CatalogGOLDAir Handling, GOLDProduct Sheetpdfproduct-sheet
Dual Unit Control BoxTBLZ-2-66Air Handling, GOLDInstructionspdfinstructions
Protocol for TBLZ-2-66 Dual Unit Control BoxModbusAir Handling, GOLDInstructionspdfinstructions
Modbus Protocol editable excel file (GOLD V1.09 or later)ModbusAir Handling, GOLDInstructionsxlsxinstructions
Modbus Protocol (GOLD V1.09 or later)ModbusAir Handling, GOLDInstructionspdfinstructions
GOLD E O&MGOLDAir Handling, GOLDInstructionspdfinstructions
GOLD DampersTBSXAir Handling, GOLDInstructionspdfinstructions
Upgrading AHU with SD cardTBLZ-1-65-2Air Handling, GOLDInstructionspdfinstructions
GOLD Roof InstallationTBTB-3Air Handling, GOLDInstructionspdfinstructions
Installation Instructions-GOLD VOC sensorTBLZ-1-60Air Handling, GOLDInstructionspdfinstructions
GOLD X ZoneTBLZ-3-50Air Handling, GOLDInstructionspdfinstructions
GOLD Room Temp. SensorTBLZ-1-24Air Handling, GOLDInstructionspdfinstructions
GOLD Exhaust Air Temperature SensorTBLZ-1-76Air Handling, GOLDInstructionspdfinstructions
GOLD Internal Temperature SensorTBLZ-1-58Air Handling, GOLDInstructionspdfinstructions
GOLD Humidity SensorTBLZ-1-31Air Handling, GOLDInstructionspdfinstructions
GOLD Temperature SensorTBLZ-1-30Air Handling, GOLDInstructionspdfinstructions
GOLD IQLogic + ModuleTBIQ-3Air Handling, GOLDInstructionspdfinstructions
GOLD RX70/80 Rotor AdjustmentGOLDAir Handling, GOLDInstructionspdfinstructions
GOLD Room Temperature SensorTBLZ-2-42Air Handling, GOLDInstructionspdfinstructions
GOLD PreheatGOLDAir Handling, GOLDInstructionspdfinstructions
Functional Profile Gateway LonWorks FTT-10 editable Excel File (GOLD pv. 1.10 or later)LonworksAir Handling, GOLDInstructionsxlsxinstructions
Functional Profile Gateway LonWorks FTT-10 (GOLD pv. 1.10 or later)LonworksAir Handling, GOLDInstructionspdfinstructions
GOLD LonWorks FTT-10TBLZ-41Air Handling, GOLDInstructionspdfinstructions
GOLD E RX/PX I&MGOLDAir Handling, GOLDInstructionspdfinstructions
GOLD E SD I&MGOLDAir Handling, GOLDInstructionspdfinstructions
Protocol v 1.10 and newer, editable Excel File (GOLD)MetasysAir Handling, GOLDInstructionsxlsxinstructions
GOLD E MetasysMetasysAir Handling, GOLDInstructionspdfinstructions
GOLD E BACnetBACnet IPAir Handling, GOLDInstructionspdfinstructions
Installation Instructions-GOLD CO2 sensor-wall mountedELQZ-2-504Air Handling, GOLDInstructionspdfinstructions
Guide to GOLD Combi CoilsGOLDAir Handling, GOLDInstructionspdfinstructions
BTL CertificateGOLDAir Handling, GOLDQualitypdfquality
ReCO2 functions for recirculation control of CO2 and VOCGOLDAir Handling, GOLDInstructionspdfinstructions

Keep Exploring

Training

Swegon offers AIA and PDH certified course to support your professional development needs.

LEARN MORE

Products you'll need to create the best indoor climate in the world.

LEARN MORE
Share
Tiffany Chan

Get to know us

  • Why Swegon?
  • References
  • Training
  • Products
  • Building-solutions
  • Standards-and-codes

More Swegon

  • About Us
  • Blog
  • Find a REP
  • Contact Us
  • Swegon on tour
  • Career

Subscribe to The Swegon Blog

Swegon Logotype White

© 2020 Swegon North America
Privacy Policy Accessible Customer Service Policy

Open toolbar

Accessibility Tools

  • Increase Text
  • Decrease Text
  • Grayscale
  • High Contrast
  • Negative Contrast
  • Light Background
  • Links Underline
  • Readable Font
  • Reset